液態鋁電解電容器-引線、焊針型 (温度125℃)

線上壽命測算
Value(uF)V(rated)ManufacturerSeriesDimension caseFreq Coeff. FRated tempRated LifeRated ripple currentActual ripple currentAmbient tempApply Ix Temp RiseLIFE EXPECTED
D(mm)L(mm)To(deg C)Lr(Hours)Io(mArms)Ix(mArms)Tx(deg C)△Tx(deg C)Lx(Hours)Lx(Years)
{{ countData[12].value || '-' }}{{ countData[13].value || '-' }}{{ countData[14].value || '-' }}
Value(uF)V(rated)ManufacturerSeriesDimension caseFreq Coeff. FRated tempRated LifeRated ripple currentActual ripple currentAmbient tempApply Ix Temp RiseLIFE EXPECTED
D(mm)L(mm)To(deg C)Lr(Hours)Io(mArms)Ix(mArms)Tx(deg C)△Tx(deg C)Lx(Hours)Lx(Years)
{{ countData[15].value || '-' }}{{ countData[16].value || '-' }}{{ countData[17].value || '-' }}
計算公式
1. Ambient Temp : 105℃<Tx≦125℃
L_x = L_r \times 1.7^{\frac{(T_o-T_x)}{10}} \times 2^{\frac{(\triangle T_o-\triangle T_x)}{5}} \\ where \triangle Tx=\triangle T₀(Ix / I₀)²

2. Ambient Temp : Tx≦105℃
L_x = L_r \times 2.89 \times 2^{\frac{(105-T_x)}{10}} \times 2^{\frac{(\triangle T_o-\triangle T_x)}{5}} \\ where \triangle Tx=\triangle T₀(Ix / I₀)²
  • Expected ripple life period (hrs) at maximum operating temperature allowed 在允許的最高使用溫度,印加額定電壓(DC)及額定紋波電流(AC) 之保証壽命
  • Expected life period (hrs) at actual operating temperature實際使用條件下的推算壽命
  • Maximum operating temperature (℃) allowed 允許的最高使用溫度(℃)
  • Actual operating ambient temperature (℃),calculate as 40℃ under 40℃。 實際使用的環境溫度(℃),低于40℃以40℃計算
  • Actual applied ripple current (mArms) at operating frequency f0 (Hz) 工作頻率 f0 (Hz) 下實際印加的濾波電流(mArms)
  • Rated maximum permissible ripple current IR(mArms) x frequency
    multiplier (Cf) at f0 (Hz) 額定紋波電流(如目錄標示值),如果在不同使用頻率時,需乘以補 正系數
    ※Ripple Current calculation: no need Temperature Multiplying Factor 濾波電流計算:不需溫度乘以因數
    ※For Ripple life,Ix Should be 80% equal or more of Io,if less than 80%, calculate with 80%. 紋波電流應該大于或者等于Io的80%,如果小於80%以80%計算
  • ≦5℃= Maximum temperature rise (℃) for applying I0 (mArms) 印加額定紋波電流時,電容所允許的溫升(小于或等于5℃)
  • The estimated life is limited to 15 years, if it exceeds 15 years, take 15 years as standard. 推算壽命以15年為上限,超過15年的以15年計之
    The actual applied ripple current shall not exceed the specification value, otherwise the formula estimation error is easy to be large and without reference value. 實際使用紋波電流請勿超過規格值,否則容易導致公式估算誤差大,而不具參考作用.